Search results for "Contrast agent"
showing 10 items of 36 documents
Synthesis, Stability and Relaxivity of TEEPO-Met: An Organic Radical as a Potential Tumour Targeting Contrast Agent for Magnetic Resonance Imaging
2018
Cancer is a widespread and life-threatening disease and its early-stage diagnosis is vital. One of the most effective, non-invasive tools in medical diagnostics is magnetic resonance imaging (MRI) with the aid of contrast agents. Contrast agents that are currently in clinical use contain metals, causing some restrictions in their use. Also, these contrast agents are mainly non-specific without any tissue targeting capabilities. Subsequently, the interest has notably increased in the research of organic, metal-free contrast agents. This study presents a new, stable organic radical, TEEPO-Met, where a radical moiety 2,2,6,6-tetraethylpiperidinoxide (TEEPO) is attached to an amino acid, methio…
The added diagnostic value of 64-row multidetector CT combined with contrast-enhanced US in the evaluation of hepatocellular nodule vascularity: impl…
2009
The aim of this study was to assess the added diagnostic value of contrast-enhanced US (CEUS) combined with 64-row multidetector CT (CT) in the assessment of hepatocellular nodule vascularity in patients with liver cirrhosis. One hundred and six cirrhotic patients (68 male, 38 female; mean age +/- SD, 70 +/- 7 years) with 121 biopsy-proven hepatocellular nodules (72 hepatocellular carcinomas, 10 dysplastic and 15 regenerative nodules, 12 hemangiomas, and 12 other benignancies) detected during US surveillance were prospectively recruited. Each nodule was scanned by CEUS during the arterial (10-40 s), portal venous (45-90 s), and delayed sinusoidal phase (from 100 s after microbubble injectio…
Texture analysis in susceptibility-weighted imaging may be useful to differentiate acute from chronic multiple sclerosis lesions.
2020
To evaluate the diagnostic performance of texture analysis (TA) applied on non-contrast-enhanced susceptibility-weighted imaging (SWI) to differentiate acute (enhancing) from chronic (non-enhancing) multiple sclerosis (MS) lesions. We analyzed 175 lesions from 58 patients with relapsing-remitting MS imaged on a 3.0 T MRI scanner and applied TA on T2-w and SWI images to extract texture features. We evaluated the presence or absence of lesion enhancement on T1-w post-contrast images and performed a computational statistical analysis to assess if there was any significant correlation between the texture features and the presence of lesion activity. ROC curves and leave-one-out cross-validation…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
Aggressive Angiomyxoma: unusual pelvic mass
2016
Learning objectives Background Findings and procedure details Conclusion Personal information References
Highly Loaded Semipermeable Nanocapsules for Magnetic Resonance Imaging.
2017
Magnetic resonance imaging has become an essential tool in medicine for the investigation of physiological processes. The key issues related to contrast agents, i.e., substances that are injected in the body for imaging, are the efficient enhancement of contrast, their low toxicity, and their defined biodistribution. Polyurea nanocapsules containing the gadolinium complex Gadobutrol as a contrast agent in high local concentration and high relaxivity up to 40 s-1 mmol-1 L are described. A high concentration of the contrast agent inside the nanocapsules can be ensured by increasing the crystallinity in the shell of the nanocapsules. Nanocapsules from aliphatic polyurea are found to display hi…
Minor changes in the macrocyclic ligands but major consequences on the efficiency of gold nanoparticles designed for radiosensitization
2016
International audience; Many studies have been devoted to adapting the design of gold nanoparticles to efficiently exploit their promising capability to enhance the effects of radiotherapy. In particular, the addition of magnetic resonance imaging modality constitutes an attractive strategy for enhancing the selectivity of radiotherapy since it allows the determination of the most suited delay between the injection of nanoparticles and irradiation. This requires the functionalization of the gold core by an organic shell composed of thiolated gadolinium chelates. The risk of nephrogenic systemic fibrosis induced by the release of gadolinium ions should encourage the use of macrocyclic chelat…
Computed tomography detects changes in contrast agent diffusion after collagen cross-linking typical to natural aging of articular cartilage
2011
SummaryObjectiveThe effect of threose-induced collagen cross-linking on the mechanical and diffusive properties of cartilage was investigated in vitro. In particular, we investigated the potential of Contrast Enhanced Computed Tomography (CECT) to detect changes in articular cartilage after increased collagen cross-linking, which is an age-related phenomenon.MethodsOsteochondral plugs (Ø=6.0mm, n=28) were prepared from intact bovine patellae (n=7). Two of the four adjacent samples, prepared from each patella, were treated with threose to increase the collagen cross-linking, while the other two specimen served as paired controls. One sample pair was mechanically tested and then mechanically …
Porphyrines et tétraazamacrocycles dérivés du DOTA : association de deux ligands pour la chélation de métaux d'intérêt en imagerie médicale multimoda…
2012
The goal of my PhD thesis was to synthesize new molecules, which give access to heterobimetallic complexes with interesting properties for multimodal imaging. In this manuscript, several main points have been studied. The first part of this work concerns the synthesis and characterization of ligands. We describe here the synthesis of five new ligands based on the association of one porphyrin and one or several cyclen derivatives. Those ligands are water-soluble. During the synthesis, we have targeted improvements to our work and developed a new synthetic pathway, which allowed us to obtain one ligand incorporating a porphyrin, a cyclen derivative and a free amine function. This function cou…